Generator |
Radiography kV Range |
44 to 125kV total 41 steps |
Radiography mA Range |
30 to 500mA total 8 steps |
Exposure Time |
0.02 to 5s total 23 steps |
Fluoroscopy kV Range |
44 to 110kV |
Fluoroscopy mA Range |
0.5 to 5mA continuous regulation |
TOMO |
Tomographic capability |
Anatomical Programing |
Yes |
Power Supply |
380VAC±38VAC, 3-phase |
Power Frequency |
50/60Hz±1Hz |
Power Capacity |
|
X-ray Tube |
|
XD52-30.50/125 XD51-20.40/125 |
Rated Voltage |
125kV 125kV |
Rated Focal Spot Value |
1.0/2.0mm 1.0/2.0mm |
Max Power(0.ls)(kW) |
30 (small) / 50 (big) 20 (small) / 40 (big) |
Rotate Speed (min1/rpm) |
2800 (50Hz) 2800 (50Hz) |
Anode Heat Storage Capacity |
190,000HU 140,000HU |
Heat Storage of Tube Assembly |
1,250,000HU 1,250,000HU |
Diagnostic Table |
Film Size and Exposure Procedure |
8" × 10" |
10" × 12" |
11" × 14" |
14" × 14" |
Send Film Method |
Film feed driven by motor; Automatic skipping |
Range of Movement |
≥720mm ( longitudinally ) |
≥200mm ( transversely ) |
≥260mm for pressure direction, Press power: 80~100N |
Pattern of Movement |
Driven electrically |
Filtering Grid |
Fixed type; grid ratio: r=8; grid density: N=40L/cm |
Focal distance: 70cm; Size: 14" ×14" |
Range of Movement |
+90° ~ 0° ~ -15° |
Pattern of Movement |
Driven electrically, at a speed of about 90°/30s |
Range of Movement |
Able to be extended 30cm at the front end |
Pattern of Movement |
Driven electrically, at a speed of about 3cm/s |
Radiographic Table |
Tabletop Length |
2000mm |
Tabletop Width |
740mm |
Tabletop Height |
658mm |
Tabletop Movement |
Longitudinal: 1200mm; Lateral: 200mm |
Strut Movement Along Table (Longitudinal) |
1200mm |
DIS Travel while X-ray Tube Assembly Vertically Moving up and down |
1100mm |
Rotation Range of X-ray Tube Around Lateral Arm |
+120° ~ -120° |
Strut Rotation Range |
+180° ~ -180° |
Tabletop Locking |
electromagnetically locking, brake pressure≥100N |
Tabletop Locking Control |
footswitch (normally closed) |
Bucky Vibration Mode |
Fixed type |
Focus |
fo=100 |
Grid Size |
14" X 17" ( 356mm × 432mm ) |
Film Loaded in Bucky |
Max 14" × 17" |
Longitudinal Travel of Bucky |
500mm |
Bucky Locking |
electromagnetically locking, brake pressure≥100N |
Image System |
Working Mode |
Continuous |
Scanning Ratio |
2.1 Interlaced |
Number of Scanning Line |
625TCL |
Number of Frame per Second |
25 |
Aspect Ratio |
4: 3 |
CCD Camera |
400,000 pixels CCD |
Resolution |
Horizontal Center≥800 TVL; Vertical Center≥400 TVL |
Image Intensifier |
Model |
Thales |
Input size |
9 inch (9”/6”/4.5”) |
Resolution |
46 lp/cm |
DQE |
65% |
Image Processing Function |
Last image hold |
8 images storage |
Dynamic function |
Static function |
Digital mask circle |
Automatic KV control |
14 inch monitor 1set |
Collimator |
|
|
Mode of Adjustment |
Manuel Electrically-Driven |
Maximum Tube Voltage |
150kV 150kV |
Radiation Field [Max SID = 65cm] |
350mm X 350mm 350mm X 350mm |
Radiation Field [Min SID = 100cm] |
0 ≤50mm X 50mm |
Time Limit of the Light Source |
≤60s N/A |
Inherent Filtration |
1.5 (mmAl) N/A |
External Dimension (L×W×H) |
250×224×250mm 212×212×223mm |