| Generator |
Radiography kV Range |
44 to 125kV total 41 steps |
| Radiography mA Range |
30 to 500mA total 8 steps |
| Exposure Time |
0.02 to 5s total 23 steps |
| Fluoroscopy kV Range |
44 to 110kV |
| Fluoroscopy mA Range |
0.5 to 5mA continuous regulation |
| TOMO |
Tomographic capability |
| Anatomical Programing |
Yes |
| Power Supply |
380VAC±38VAC, 3-phase |
| Power Frequency |
50/60Hz±1Hz |
| Power Capacity |
|
| X-ray Tube |
|
XD52-30.50/125 XD51-20.40/125 |
| Rated Voltage |
125kV 125kV |
| Rated Focal Spot Value |
1.0/2.0mm 1.0/2.0mm |
| Max Power(0.ls)(kW) |
30 (small) / 50 (big) 20 (small) / 40 (big) |
| Rotate Speed (min1/rpm) |
2800 (50Hz) 2800 (50Hz) |
| Anode Heat Storage Capacity |
190,000HU 140,000HU |
| Heat Storage of Tube Assembly |
1,250,000HU 1,250,000HU |
| Diagnostic Table |
Film Size and Exposure Procedure |
8" × 10" |
| 10" × 12" |
| 11" × 14" |
| 14" × 14" |
| Send Film Method |
Film feed driven by motor; Automatic skipping |
| Range of Movement |
≥720mm ( longitudinally ) |
| ≥200mm ( transversely ) |
| ≥260mm for pressure direction, Press power: 80~100N |
| Pattern of Movement |
Driven electrically |
| Filtering Grid |
Fixed type; grid ratio: r=8; grid density: N=40L/cm |
| Focal distance: 70cm; Size: 14" ×14" |
| Range of Movement |
+90° ~ 0° ~ -15° |
| Pattern of Movement |
Driven electrically, at a speed of about 90°/30s |
| Range of Movement |
Able to be extended 30cm at the front end |
| Pattern of Movement |
Driven electrically, at a speed of about 3cm/s |
| Radiographic Table |
Tabletop Length |
2000mm |
| Tabletop Width |
740mm |
| Tabletop Height |
658mm |
| Tabletop Movement |
Longitudinal: 1200mm; Lateral: 200mm |
| Strut Movement Along Table (Longitudinal) |
1200mm |
| DIS Travel while X-ray Tube Assembly Vertically Moving up and down |
1100mm |
| Rotation Range of X-ray Tube Around Lateral Arm |
+120° ~ -120° |
| Strut Rotation Range |
+180° ~ -180° |
| Tabletop Locking |
electromagnetically locking, brake pressure≥100N |
| Tabletop Locking Control |
footswitch (normally closed) |
| Bucky Vibration Mode |
Fixed type |
| Focus |
fo=100 |
| Grid Size |
14" X 17" ( 356mm × 432mm ) |
| Film Loaded in Bucky |
Max 14" × 17" |
| Longitudinal Travel of Bucky |
500mm |
| Bucky Locking |
electromagnetically locking, brake pressure≥100N |
| Image System |
Working Mode |
Continuous |
| Scanning Ratio |
2.1 Interlaced |
| Number of Scanning Line |
625TCL |
| Number of Frame per Second |
25 |
| Aspect Ratio |
4: 3 |
| CCD Camera |
400,000 pixels CCD |
| Resolution |
Horizontal Center≥800 TVL; Vertical Center≥400 TVL |
| Image Intensifier |
Model |
Thales |
| Input size |
9 inch (9”/6”/4.5”) |
| Resolution |
46 lp/cm |
| DQE |
65% |
| Image Processing Function |
| Last image hold |
| 8 images storage |
| Dynamic function |
| Static function |
| Digital mask circle |
| Automatic KV control |
| 14 inch monitor 1set |
| Collimator |
|
|
| Mode of Adjustment |
Manuel Electrically-Driven |
| Maximum Tube Voltage |
150kV 150kV |
| Radiation Field [Max SID = 65cm] |
350mm X 350mm 350mm X 350mm |
| Radiation Field [Min SID = 100cm] |
0 ≤50mm X 50mm |
| Time Limit of the Light Source |
≤60s N/A |
| Inherent Filtration |
1.5 (mmAl) N/A |
| External Dimension (L×W×H) |
250×224×250mm 212×212×223mm |