Steam Sterilizers Autoclaves

0 Submit Review |  Submit Review
In stock
1. Substantial Chamber Capacity
This sterilizer, which has a practical medium sized chamber between large and small sized sterilizer and is very effective to load the volumed loads, uses the saturated vapor as sterilant supplied from the built-in steam generator or external steam supply system. The chamber with jacket is the most sound structurally and the door is sealed firmly by a locking system with radial levers.
 
 

1. Substantial Chamber Capacity
This sterilizer, which has a practical medium sized chamber between large and small sized sterilizer and is very effective to load the volumed loads, uses the saturated vapor as sterilant supplied from the built-in steam generator or external steam supply system. The chamber with jacket is the most sound structurally and the door is sealed firmly by a locking system with radial levers.



2. Variable Cycle Programs and Self-Diagnosis Program
This sterilizer has 5 kinds of optimized basic cycle program for sterilizing general medical instruments and 2 kinds of test program are embedded in the controls of sterilizer. Therefore operator can select a proper cycle conveniently for sterilizing a load and change the parameters of program easily according to the sterilizing condition. The self-diagnosis program generates the warning signal, displays the error code on the control panel and aborts the executing cycle for safety automatically in case that any operating error has occurred during cycle executing.



3. Safety
The door would not be opened without power supplying and cycle does not start unless the door is locked. The door locking system is designed to seal the chamber simply by the radial lever type. To open the door safely under chamber pressure, turn the door handle counter clockwise, then the radial levers are released and the vapor is leaked through the gap between chamber edge and door. Strong opening/closing mechanism and heat-blocking door plate cover would protect the operator from a possible accident during sterilizing. In case the chamber pressure exceeds in the set value, the safety valve exhausts the vapor from the chamber and then decreases the chamber pressure.



4. Built-in Printer
The built-in panel printer prints out the cycle performance record for securing the traceability afterward
There are yet no reviews for this product.

We are export Medical And Dental Equipment And material provider since 35 year we are the first and the only company in this field at that time. We serve the majority of hospitals and medical center including furnishing and equipping through direct sales and through tenders via the Ministry of Health and through the NGOs Our fingerprints on 85% from all Yemen Hospitals and Health Centers in All cities and Villages.

Contacts

  • Email  : info@alamarymed.com
  • Phone :  +967 1 278147 
  • Fax     : +967 1 277974  
  • Mobile :  +967 733 819 573
  • Address :AL-Quasar Street in front of presidency office behind Arab bank Sana'a Yemen.
Top
We use cookies to improve our website. By continuing to use this website, you are giving consent to cookies being used. More details…